Screw Pile Foundations: How They Work and When They Fit a Colorado Build

Drum Point screw-pile lighthouse on its red iron pile frame at the Calvert Marine Museum in Solomons, Maryland
Drum Point Lighthouse, one of the surviving Chesapeake Bay screw-pile lighthouses, now at the Calvert Marine Museum in Solomons, Maryland. Iron screw piles held lights like this one above the water long before anyone used them under houses. Photo: ShoreDweller05, via Wikimedia Commons · Source · CC BY-SA 4.0 · Resized

A screw pile foundation is a set of steel piles with helix plates welded near the tip, turned into the ground by a hydraulic drive head until each one reaches the depth and torque the engineer specified. The structure then sits on caps or a grade beam tied to the pile tops. “Screw pile” and “helical pile” name the same product. On the Front Range they’re used for new homes, additions, decks and commercial buildings where the soil near the surface swells, freezes or is too soft to carry a footing. This guide covers how a screw pile carries load, what the building code asks, how screw piles differ from ground screws, and when they’re the right pick.

What is a screw pile foundation?

Each pile has three working parts. The lead section is the bottom length of shaft, with one or more round helix plates near the tip. Extensions are plain shaft lengths bolted on as the pile goes deeper. The cap or bracket at the top connects the pile to the concrete or steel the building sits on.

The idea is old. Iron screw piles were first used for lighthouses and harbor piers, and more than 100 screw-pile lighthouses went up on the US east coast between the 1850s and 1890s. The modern version is a code-recognized deep foundation. The building code’s helical pile sections (IBC 1810.3.1.5 and 1810.3.3.1.9) apply to it directly, and products are evaluated against ICC-ES acceptance criteria AC358.

For a house, the piles go in first. Then your concrete contractor forms a grade beam or pile caps around the pile tops, and framing goes on that. Site Safe Helical Piers installs the piles; we don’t pour the concrete.

How screw piles carry the load

The helix plates do most of the work. Each one bears on the soil around it, a bit like a small buried footing. Section 1810.3.3.1.9 of the building code says a helical pile’s allowable load is half of its ultimate capacity, and the ultimate capacity is the smallest of six values:

  1. Base capacity (the total helix plate area times the bearing capacity of the soil they sit in) plus shaft friction above the top plate.
  2. Capacity from well-documented correlations with installation torque.
  3. Capacity from load tests, where the code requires them.
  4. The axial capacity of the shaft.
  5. The axial capacity of the couplings.
  6. The combined axial capacity of the helix plates.

Item 2 is the one used on most jobs. As the helices move into firmer soil, the drive head has to push harder to turn them. AC358 ties final installation torque to capacity with a ratio called Kt:

ShaftDefault Kt (AC358 3.13.1.1)
1.5 in or 1.75 in square10 per ft
2.875 in round9 per ft
3.0 in round8 per ft
3.5 in round7 per ft

Ultimate capacity equals Kt times the final torque. So a 2.875 inch round shaft that finishes at 4,000 ft-lb has an ultimate capacity of 36,000 lb, and an allowable capacity of half that, 18,000 lb, unless the shaft, a coupling or the plates limit it lower. Those numbers are arithmetic only. Your engineer and the product’s evaluation report set the real ones.

Screw piles vs ground screws

Some products sold for sheds, fences and small decks are “ground screws”: a tapered tube with a continuous thread running up it, more like a giant wood screw. They work for light structures, but they don’t fit AC358’s torque correlation criteria. Table 3 of AC358 asks for true helix-shaped plates 8 to 14 inches in diameter and 3/8 to 1/2 inch thick, a 3 inch pitch, and plates spaced 2.4 to 3.6 helix diameters apart, with the smallest one at the bottom.

Screw pile (helical pile)Ground screw
Bearing elementSeparate helix plates near the tipContinuous thread along a tapered body
DepthExtended on site until it reaches torque and design depthFixed length per product
AC358 default KtApplies if the system meets Table 3Doesn’t meet Table 3 geometry
Typical useHouses, additions, decks, commercial, solarSheds, fences, light structures
Capacity checkTorque log on every pileProduct data, sometimes a pull test

If your plans say “helical piles per ESR-xxxx,” a ground screw isn’t a substitute. Ask the supplier for the evaluation report number.

Screw piles for house foundations: what the code asks

For homes built under the residential code, Denver’s R401.4 calls for a soils test by an approved agency, and R403.1.8 says foundations on expansive soil must be designed under IBC Section 1808.6. On most Front Range lots, that means a geotechnical report and an engineered foundation before any pile gets ordered. Our post on why soil testing comes before a new home explains what the report covers.

Evaluation reports cover the residential side too. ESR-2794, for one product line, says its helical systems may be used under the IRC as an alternate foundation system supporting light-frame construction. That’s how a wood-framed house ends up on piles with a regular building permit.

Installation has its own rules. IBC 1810.4.11 says installers can’t exceed the manufacturer’s rated maximum installation torque. AC358 Table 3 adds that, for the torque correlation to hold, the pile has to advance at least 85 percent of the helix pitch per revolution when final torque is measured, and turn at less than 25 revolutions per minute. A pile that spins in place without advancing is chewing up soil, and its torque reading doesn’t mean much.

Why screw piles suit Front Range ground

Two things push Colorado builders toward deep foundations: frost and clay.

Denver’s design frost depth is 36 inches (Table R301.2), so a footing or pile has to bear below that. Screw piles go well past it as a matter of course.

Clay is the bigger problem. The Colorado Geological Survey says expansive soils can swell up to 20 percent by volume when wet, that engineers treat swell of 3 percent or more as potentially damaging, and that the clay can push with pressures of 20,000 pounds per square foot or more. A shallow footing sits in that zone. A screw pile carries the building down past it to soil that doesn’t move with the seasons, and the engineer sets a minimum depth so the helices end up bearing below the swelling layer.

There are practical gains on a tight lot as well. Screw piles leave no drill spoils to haul and need no cure time before they carry load. Wikipedia’s summary of their benefits also lists little dependence on weather, which matters when a Front Range schedule runs into winter.

When a screw pile foundation is the right call

Site or projectScrew piles a good fit?Why
Swelling clay near the surfaceUsuallyBearing goes below the active zone; each pile is torque-verified
Addition next to an existing houseUsuallySmall equipment, little vibration, no open holes near the old footing
Deck, porch or pergolaYesQuick installs, below frost depth, no concrete wait
Sloped or tight-access lotOftenCompact rigs, no spoils, piles set to varying heights
Tight scheduleOftenNo concrete cure before the pile carries load
Dense cobbles, boulders or shallow hard rockSometimesPlates can hit refusal early; may need pre-drilling or a different element
Very heavy column loadsCase by caseMay need pile groups or larger shafts
Highly corrosive soilNeeds special designOutside AC358’s standard scope

The soils report usually settles it. If it shows stable, non-swelling soil at shallow depth, a conventional footing may cost less. If it shows swelling clay, groundwater or soft fill, piles start to make sense.

What a screw pile installation looks like

On a typical new build, the day runs in a set order:

  1. Layout. Pile locations get staked from the foundation plan.
  2. Lead sections in. The rig sets each lead plumb and starts turning it.
  3. Extensions. Shaft lengths get bolted on as the pile advances.
  4. Termination. Each pile stops when it reaches the engineer’s minimum depth and torque.
  5. Cut and cap. Piles are cut to elevation and fitted with new-construction caps or brackets.
  6. Hand-off. The concrete contractor forms and pours the caps or grade beam.

Before anyone pours, check the installation log. For each pile it should show the location number, the product and helix configuration, total depth, final torque (and how it was measured), and any pile that hit refusal or had to be moved. Keep that log with your permit set.

What drives screw pile foundation cost

The price depends on how many piles the design needs, how deep they have to go to reach torque, shaft size, site access and whether the soil has cobbles. A house usually needs more and longer piles than a deck. We cover those factors in more detail in our post on helical screw pile costs. For a real number, you need the pile layout from your engineer and a soils report.

Building on screw piles in Colorado?

Site Safe Helical Piers installs screw piles and helical piles for new homes, additions, decks, solar and commercial buildings along the Colorado Front Range. We put the piles in to your engineer’s depth and torque and hand over the log; your concrete contractor builds the caps or grade beam on top. See our services, contact us or call 970-673-5615.

FAQ

Are screw piles as good as concrete?

On Front Range clay they often are. Both are recognized deep foundations in the building code. A screw pile’s capacity is checked on every pile by its installation torque, while a concrete pier’s capacity comes from the design and the soils report. Your engineer picks the one that suits the loads and soil.

How deep do screw piles need to go?

Deep enough to meet the engineer’s minimum depth and minimum torque at the same time. In Denver that’s always below the 36-inch frost line, and on swelling clay it’s usually much deeper, past the soil that moves with moisture.

What are the disadvantages of screw piles?

They can hit refusal on cobbles or shallow rock before reaching depth. Their slender shafts take limited sideways load: Wikipedia puts typical small-diameter piles at up to 300 kN axial but only about 25 kN lateral. Highly corrosive soils need special design. And on a lot with stable soil near the surface, a conventional footing can cost less.

How much do screw piles cost?

It depends on pile count, depth, shaft size and access, so there’s no honest per-pile number without a design. Get the engineer’s pile layout and the soils report, then ask for a quote based on them.

Sources

  1. ICC-ES AC358 Acceptance Criteria for Helical Pile Systems and Devices (published April 2025), Sections 3.13.1.1, 4.4.1 and Table 3
  2. Denver Commercial Building Code 2025 (2024 IBC with Denver amendments), Chapter 18, 1810.3.1.5, 1810.3.3.1.9 and 1810.4.11 Helical piles
  3. Denver Residential Code 2025 (2024 IRC with Denver amendments), Chapter 3, Table R301.2 (frost line depth 36 in)
  4. Denver Residential Code 2025 (2024 IRC with Denver amendments), Chapter 4: R401.4 soil tests, R403.1.8 expansive soils
  5. ICC-ES ESR-2794, CHANCE Helical Foundation Systems, Section 2.2 IRC use
  6. Colorado Geological Survey, Expansive Soil and Rock
  7. Wikipedia, Screw piles (history: screw-pile lighthouses on the US east coast, 1850s to 1890s)

Topics: screw piles, helical piles, new construction, deep foundations, expansive soil, Colorado

Get your free estimate

You’ll see why we’ve earned the reputation as being one of the top new construction foundation companies in Colorado & why we offer a rock solid guarantee to back it up.

Call now

970-673-5615

Free estimate